Company Details

  • Etone Power Co., Ltd.

  •  [Guangdong,China]
  • Business Type:Manufacturer , Trade Company , Service
  • Main Mark: Africa , Americas , Asia , Middle East , Oceania , Other Markets
  • Exporter:31% - 40%
  • Certs:CE, ISO9001, ISO14000
  • Description:16kw Offline Uninterruptible Power,16kw Tower UPS,16kw Spare Off-Line Power
Inquiry Basket ( 0 )

Etone Power Co., Ltd.

16kw Offline Uninterruptible Power,16kw Tower UPS,16kw Spare Off-Line Power

Home > Products > Off line UPS(500W-1000W) > 16kw Offline Uninterruptible Power

16kw Offline Uninterruptible Power

Share to:  
    Payment Type: L/C,T/T
    Incoterm: FOB,CFR
    Min. Order: 1 Set/Sets

Basic Info

Model No.: ET33-20KS

Type: Self-Starting Diesel Generator

Installation Method: Fixed

Stroke: Four Stroke

Cooling Method: Water Cooling

Output Type: AC Three Phase

Speed: Speed

Conditions of Use: Land Use

Usage: Standby Unit

Landuse Type of Unit: Ordinary

Excitation Mode: AC Rotating Exciter

Additional Info

Transportation: Ocean,Land

Place of Origin: china

Product Description

16kw Offline Uninterruptible Power: Etone Offline UPS covers from the small devices beneath your desk protecting your computer to 8-ton versions designed to temporarily provide a megawatt of power to large data centers. The UPS can work normally under a lacking phase state.

In the event of a power failure, Uninterruptible Power Supplies (UPS) provide emergency instantaneous power to critical devices - computers, data centers, and telecommunications equipment - through energy that is typically stored in a battery. UPS temporarily provide this power to allow for proper equipment shut down (e.g., computers) or for a standby power generator to start up (e.g., at data centers). In addition, UPS are able to protect against power surges, voltage drops, and frequency distortions. ETONE UPS can cut energy losses by 30-55%. A 1000 kVA UPS used in a large data center could save $18,000 annually.



PT33-20KS

Model
(3 Phase Input/

3 Phase Output)

ET33--20KS

Comments

Input voltage

Rated voltage

380VAC/220VAC

Phase

three phase with ground

Turn on voltage range

(120±5~274±5)VAC

Bypass voltage range

(60±5~300±5)VAC

Could be adjusted by software.

Bypass low loss

60VAC~220VAC(default 60VAC)

Bypass low comeback

Low loss -10VAC

Bypass high loss

220VAC~300VAC(default 300VAC)

Bypass high comeback

High loss -10VAC

Input frequency

Rated frequency

50Hz

Frequency low loss

(40~49) ±0.2Hz(default:46Hz)

Could be adjusted by software.

Frequency low comeback

Frequency low loss +0.5Hz

Frequency high loss

(51~60)±0.2Hz(default:54Hz)

Frequency high comeback

Frequency high loss -0.5Hz

Input Performance

Input power factor

> 0.99

220VAC,full R load

Input THDI

<= 10%

Output power

VA/watt

20KVA
/16KW

Rated voltage

220VAC

Sine wave

Voltage range

200/208/220/230/240VAC

Could be adjusted by software.

10% derating for 208VAC/200VAC.

Voltage regulation

±1%

Voltage distortion

≤5%

Full RCD load

≤3%

Full R load

Transient response

≤9%

R load 0%~100%~0%

≤6%

R load 20%~100%~20%

Transient recovery

≤60ms voltage recovery to 90%

Full RCD load

Bypass output before turn-on

YES

Output frequency range

Normal mode

1,Same as input frequency(46Hz~54Hz)

2,50Hz(InputInputfrequency<46Hz)frequency>54Hz or

Battery mode

(50+0.1) Hz

Slew rate

1 Hz/Sec

Efficiency

Normal mode

> 91%

Battery mode

> 89%

Overload

Normal mode/battery mode

Overload warning only

105%±5%≤load

1min,then transfer to bypass and alarm.

105%±5%

30S,then transferto bypass and alarm.

125%±5%

300mS, then transfer to bypass and alarm.

load>150%±5%

Automatically retransfer

YES

Environment

Work temperature

0℃~40℃

Altitude

<1000m

Audible noise

≤60dB

Storage temperature

-15℃~45℃

Work humidity

20%~95%

EMS

ESD

IEC61000-4-2

Level4

RS

IEC61000-4-3

Level3

EFT

IEC61000-4-4

Level4

Surge

IEC61000-4-5

Level4

EMI

Conducted

EN55022

Class A

Radiated

EN55022

Class A

Safety

GB4943-2001 / IEC62040-1

Size length * width * height
(mm)

710*260*717

input parameters

input voltage

380V AV

input wire line diameter

4mm2

input npl line diameter

10mm2

input earth line diameter

4mm2

input breaker

50A -3:3

output parameters

output voltage

380V AV

output wire line diameter

4mm2

output npl line diameter

10mm2

output earth line diameter

4mm2

output breaker

50A -3:3

battery parameters

External battery breaker

125A-3:3

External battery line diameter

4mm2

Packing-Shipping

QQ20170220084947

QQ20170220084922


Our Services

1

2

3

4

20170220140438

Our Company Etone Power, who is a professional manufacturer specialized in Generator set design, produce, sales, installation, maintenance and service. Over 20 years field experience, set up reliable partnership with Cummins, Perkins, Deutz, Mitsubishi, Stamford, Leroy Somer and Marathon series world famous engines and AC alternators brand. Beside ATS, our products cover Cummins Diesel Generator Set, Perkins Diesel Generator Set, Deutz Diesel Generator Set(Open, Silent, Containers type, Trailer type), Gas generator set/Gasoline Portable Generator, Brushless Alternator/Genset Controller, Generator Set Accessories, Trailer Light Tower, Backup UPS.


Looking for ideal 16kw Offline Uninterruptible Power Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the 16kw Tower UPS are quality guaranteed. We are China Origin Factory of 16kw Spare Off-Line Power. If you have any question, please feel free to contact us.

Product Categories : Off line UPS(500W-1000W)

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Kitty Ms. Kitty
What can I do for you?
Contact Supplier